TESLA Warning

BMS_w123

BMS_w123_SW_Internal_Isolation

System
BMS
Battery Management System
Type
Warning
Category
Battery
Severity
Warning

What does BMS_w123 mean?

Tesla warning code in the Battery Management System (BMS) module. The Battery Management System (BMS) has detected that the isolation resistance internal to the high voltage (HV) battery has exceeded the threshold while the contactors are open. If this alert is present, the isolation has dropped below 190 kOhm with the contactors open. The alert will clear when the isolation exceeds 380 kOhm threshold while the contactors are open.

Original Description

The Battery Management System (BMS) has detected that the isolation resistance internal to the high voltage (HV) battery has exceeded the threshold while the contactors are open. If this alert is present, the isolation has dropped below 190 kOhm with the contactors open. The alert will clear when the isolation exceeds 380 kOhm threshold while the contactors are open.

Severity Notes

BMS_w123 is a Warning in the Battery Management System system. Schedule service soon. Monitor your vehicle for additional warnings.

Other BMS Codes

View all BMS codes →

Tesla alert codes sourced from the community-maintained Tesla Alerts Dictionary. This information is for educational purposes only. Always consult Tesla Service for official diagnosis and repairs.