TESLA Fault

CHG_f125

CHG_f125_leakageTestFailure

System
CHG
Charger
Type
Fault
Category
Charging
Severity
Fault (Critical)

What does CHG_f125 mean?

Tesla fault code in the Charger (CHG) module. This fault indicates that the voltage decay after the supercharger external isolation test has happened too quickly. During supercharger startup, the supercharger will open the output contactors after performing the external isolation test at 300V. The vehicle then monitors the time it takes for the 300V to decay. If the decay time is sufficient, the start-up sequence proceeds. The purpose of this test is to check the common mode isolation (DC+ to DC-) of the high voltage chain from the supercharger cabinet to the vehicle's fast charge contactors.

Original Description

This fault indicates that the voltage decay after the supercharger external isolation test has happened too quickly. During supercharger startup, the supercharger will open the output contactors after performing the external isolation test at 300V. The vehicle then monitors the time it takes for the 300V to decay. If the decay time is sufficient, the start-up sequence proceeds. The purpose of this test is to check the common mode isolation (DC+ to DC-) of the high voltage chain from the supercharger cabinet to the vehicle's fast charge contactors.

Severity Notes

CHG_f125 is classified as a Fault, indicating a critical issue in the Charger system. Do not continue driving and contact Tesla Service immediately.

Other CHG Codes

View all CHG codes →

Tesla alert codes sourced from the community-maintained Tesla Alerts Dictionary. This information is for educational purposes only. Always consult Tesla Service for official diagnosis and repairs.