TESLA Fault

DI_f127

DI_f127_gracefulPowerOff

System
DI
Drive Inverter
Type
Fault
Category
Motor
Severity
Fault (Critical)

What does DI_f127 mean?

Tesla fault code in the Drive Inverter (DI) module. The motor controller asserts this condition whenever any of the following alerts or controller area network (CAN) signals are present: No Battery Power (any amount of time). GTW_notEnough12VforDrive (any amount of time). Whenever any of the temperatures below exceed their Graceful Power Off thresholds for specified time: Outlet fluid (2 seconds)Internal ambient (2 seconds)Any of the IGBT heatsinks (3 seconds)Stator (2 seconds)Fluid delta T too positive (2 seconds)

Original Description

The motor controller asserts this condition whenever any of the following alerts or controller area network (CAN) signals are present: No Battery Power (any amount of time). GTW_notEnough12VforDrive (any amount of time). Whenever any of the temperatures below exceed their Graceful Power Off thresholds for specified time: Outlet fluid (2 seconds)Internal ambient (2 seconds)Any of the IGBT heatsinks (3 seconds)Stator (2 seconds)Fluid delta T too positive (2 seconds)

Severity Notes

DI_f127 is classified as a Fault, indicating a critical issue in the Drive Inverter system. Do not continue driving and contact Tesla Service immediately.