DIS_f126
DIS_f126_limpMode
What does DIS_f126 mean?
Tesla fault code in the Drive Inverter Secondary (DIS) module. The motor controller shall assert this condition whenever any of the following alerts are present:Phase Current ImbalanceBus Voltage Sensor IrrationalNo Functional Stator Temperature SensorsNo Functional Isolated Gate Bipolar Transistor (IGBT) Heatsink Temperature SensorsNo Fluid in IGBT Heatsink12V Supply UndervoltageBattery Management System missing (MIA)Low Fluid Flow This alert is also triggered whenever any of the temperatures below exceed their Limp thresholds for the specified time:Outlet fluid (2 seconds)Internal ambient (2 seconds)
Original Description
The motor controller shall assert this condition whenever any of the following alerts are present:Phase Current ImbalanceBus Voltage Sensor IrrationalNo Functional Stator Temperature SensorsNo Functional Isolated Gate Bipolar Transistor (IGBT) Heatsink Temperature SensorsNo Fluid in IGBT Heatsink12V Supply UndervoltageBattery Management System missing (MIA)Low Fluid Flow This alert is also triggered whenever any of the temperatures below exceed their Limp thresholds for the specified time:Outlet fluid (2 seconds)Internal ambient (2 seconds)
Severity Notes
DIS_f126 is classified as a Fault, indicating a critical issue in the Drive Inverter Secondary system. Do not continue driving and contact Tesla Service immediately.
Other DIS Codes
Tesla alert codes sourced from the community-maintained Tesla Alerts Dictionary. This information is for educational purposes only. Always consult Tesla Service for official diagnosis and repairs.