TESLA Alarm

BMS-A122

BMS_a122_SW_BMS_Therm_Irrational

System
BMS
Battery Management System
Typ
Alarm
Kategorie
Batterie
Schweregrad
Alarm

Was bedeutet BMS-A122?

Tesla Alarm-Code im Batteriemanagementsystem-Modul (BMS). Indicate that a thermistor reading is irrational BMS cannot measure the temperature on any modules BMS has faulted while charging or attempting to charge due to a fault BMS does not receive the UI charge request message BMS receives the UI charge request message BMS does not receive charging-related requests from the UI Indicates a BMB reference voltage was out of bounds BMS has detected that one or more bricks' voltage is above the warning threshold Wall connector contactor output shows no voltage when expected to be closed on one or more phases No voltage is seen on Wall Connector output when contactors are expected to be closed Voltage is seen at the wall connector output or contactors switch to open state Wall connector will not operate Wall connector charge handle temperature too high info from manualCC_A013 Wall connector charge handle temperature exceeds 78 C Wall connector charge handle temperature falls below 58 C or user interaction if charging was stopped Wall connector will reduce reported current capability in 25 percent increments until condition clears or current reaches zero and charging is stopped Master unit current limit set too low info from manualCC_A024 Master unit current limit divided by number of units in the sharing network is less than 6 A Master unit current limit set high enough to allow 6 A or greater per unit in the network Input wiring terminals are too hot as detected by non-contact IR sensor info from manualCC_A041 Input wiring terminal IR emission exceeds threshold Input wiring terminal IR emission falls below threshold Charging rate will be reduced by 50% and one red blink on LEDs Wall connector PCBA temperature too high info from manualCC_A011 Wall connector PCBA temperature exceeds 100 C Wall connector PCBA temperature falls below 80 C or user interaction if charging was stopped Wall connector input wiring connections are incorrect info from manualCC_A009 Wall connector line and neutral conductors are swapped Wall connector input wiring is corrected Wall connector will not operate while input wiring is swapped Wall connector microcontroller internal self test fault info from manualCC_A014 Wall connector microcontroller failed internal self test Wall connector microcontroller passes internal self test Wall connector will not operate until self test passes AC line PLL failed to lock. Check grid frequency and quality. PLL was unable to identify valid grid frequency and phase AC line PLL successfully locks GFCI cannot function without locked PLL, Wall Connector will not operate Wall connector input terminal temperature sensor shorted, open, or too cold info from manualCC_A026 Input terminal temperature sensor measured as open or short circuit Wall connector input terminal temperature reading passes rationality check Vehicle side protective earth is disconnected from wall connector info from manualCC_A002 Vehicle side protective earth is disconnected or high impedance Vehicle side protective earth is connected Wall connector will not allow charging until vehicle side protective earth is connected More than three units configured as slaves were detected on the sharing network info from manualCC_A023 More than three units are configured as slaves in the sharing network Three or fewer slave units are detected on the sharing network info from manualCC_A028 Wall connector current limit selection dial is set to an invalid position Rotary dial changed to valid setting and unit is power cycled Microcontroller supply rail is incorrect info from manualCC_A020 Microcontroller supply voltage is outside of valid range Microcontroller supply voltage enters valid range Wall Connector WiFi module hasn't checked in with the real-time processor WiFi module has failed to check in due to a long running process, update, or software bug WiFi module checks in with the real-time processor Charging will continue normally, but connectivity and billing may be delayed or unavailable Wall connector charge handle temperature sensor shorted, open, or too cold info from manualCC_A027 Charge handle temperature sensor measured as open or short circuit Wall connector charge handle temperature reading passes rationality check AC RMS input voltage is too low info from manualCC_A008 AC RMS input voltage fell below 160 V RMS for more than 2 seconds AC RMS input voltage rises above 170 V RMS for more than 2 seconds Wall connector will not allow charging while the input voltage is too low Ground fault detection circuit self test failed info from manualCC_A004 Ground fault detection circuit self test passed after being re-run. Test re-runs after 15 minutes (non-EU), cable cycle, or reset button. Wall connector will not allow charging until the ground fault circuit self test passes info from manualCC_A029 Pilot level transitions to invalid voltage level Wall connector will not operate while pilot level is invalid Wall connector PCBA temperature sensor shorted, open, or too cold info from manualCC_A025 PCBA temperature sensor measured as open or short circuit Wall connector PCBA temperature reading passes rationality check info from manualCC_A015 Neutral conductor is grounded on vehicle side info from manualCC_A005 Neutral conductor conductor impedance to ground on vehicle side is less than 2 Ohms with contactors open Neutral conductor impedance to ground on vehicle is greater than 2 Ohms with contactors open Wall connector will not allow charging if there is a short between neutral and protective earth when a vehicle is connected before closing contactors Wall connector proximity line disconnected or vehicle is not providing proximity voltage info from manualCC_A019 Proximity line in charge cable has no voltage present but a vehicle is connected Proximity line in charge cable rises to a valid voltage level Wall connector will not allow charging while the proximity line is broken because it cannot determine if the cable is latched Wall connector charge handle is too hot Wall Connector handle temperature exceeds 65C Wall connector handle temperature falls below 60C Ground fault current exceeded threshold info from manualCC_A003 Ground fault current has been corrected and the test re-run. Test re-runs after 15 minutes (non-EU), cable cycle, or reset button. Wall connector will not allow charging until ground fault current path is corrected and the test re-run. info from manualCC_A018 Master and slave units in sharing network have different nameplate current ratings info from manualCC_A030 Wall connector nameplate current rating differs from other wall connector in sharing network Wall connector no longer detects units with different nameplate current rating in the sharing network and the unit is power cycled Wall connector protective earth is disconnected or grounding scheme DIP switch set incorrectly info from manualCC_A001 Wall connector AC input side ground impedance is above threshold Wall connector AC input side ground impedance has fallen below threshold for adequate time Wall connector will not allow charging until the protective earth connection is corrected Output voltage, current, and energy monitoring failure Metering hardware fails to initialize Metering hardware initializes successfully Wall Connector cannot detect welds, over-current, or meter energy. Wall Connector will not operate.

Originale Beschreibung

Indicate that a thermistor reading is irrational BMS cannot measure the temperature on any modules BMS has faulted while charging or attempting to charge due to a fault BMS does not receive the UI charge request message BMS receives the UI charge request message BMS does not receive charging-related requests from the UI Indicates a BMB reference voltage was out of bounds BMS has detected that one or more bricks' voltage is above the warning threshold Wall connector contactor output shows no voltage when expected to be closed on one or more phases No voltage is seen on Wall Connector output when contactors are expected to be closed Voltage is seen at the wall connector output or contactors switch to open state Wall connector will not operate Wall connector charge handle temperature too high info from manualCC_A013 Wall connector charge handle temperature exceeds 78 C Wall connector charge handle temperature falls below 58 C or user interaction if charging was stopped Wall connector will reduce reported current capability in 25 percent increments until condition clears or current reaches zero and charging is stopped Master unit current limit set too low info from manualCC_A024 Master unit current limit divided by number of units in the sharing network is less than 6 A Master unit current limit set high enough to allow 6 A or greater per unit in the network Input wiring terminals are too hot as detected by non-contact IR sensor info from manualCC_A041 Input wiring terminal IR emission exceeds threshold Input wiring terminal IR emission falls below threshold Charging rate will be reduced by 50% and one red blink on LEDs Wall connector PCBA temperature too high info from manualCC_A011 Wall connector PCBA temperature exceeds 100 C Wall connector PCBA temperature falls below 80 C or user interaction if charging was stopped Wall connector input wiring connections are incorrect info from manualCC_A009 Wall connector line and neutral conductors are swapped Wall connector input wiring is corrected Wall connector will not operate while input wiring is swapped Wall connector microcontroller internal self test fault info from manualCC_A014 Wall connector microcontroller failed internal self test Wall connector microcontroller passes internal self test Wall connector will not operate until self test passes AC line PLL failed to lock. Check grid frequency and quality. PLL was unable to identify valid grid frequency and phase AC line PLL successfully locks GFCI cannot function without locked PLL, Wall Connector will not operate Wall connector input terminal temperature sensor shorted, open, or too cold info from manualCC_A026 Input terminal temperature sensor measured as open or short circuit Wall connector input terminal temperature reading passes rationality check Vehicle side protective earth is disconnected from wall connector info from manualCC_A002 Vehicle side protective earth is disconnected or high impedance Vehicle side protective earth is connected Wall connector will not allow charging until vehicle side protective earth is connected More than three units configured as slaves were detected on the sharing network info from manualCC_A023 More than three units are configured as slaves in the sharing network Three or fewer slave units are detected on the sharing network info from manualCC_A028 Wall connector current limit selection dial is set to an invalid position Rotary dial changed to valid setting and unit is power cycled Microcontroller supply rail is incorrect info from manualCC_A020 Microcontroller supply voltage is outside of valid range Microcontroller supply voltage enters valid range Wall Connector WiFi module hasn't checked in with the real-time processor WiFi module has failed to check in due to a long running process, update, or software bug WiFi module checks in with the real-time processor Charging will continue normally, but connectivity and billing may be delayed or unavailable Wall connector charge handle temperature sensor shorted, open, or too cold info from manualCC_A027 Charge handle temperature sensor measured as open or short circuit Wall connector charge handle temperature reading passes rationality check AC RMS input voltage is too low info from manualCC_A008 AC RMS input voltage fell below 160 V RMS for more than 2 seconds AC RMS input voltage rises above 170 V RMS for more than 2 seconds Wall connector will not allow charging while the input voltage is too low Ground fault detection circuit self test failed info from manualCC_A004 Ground fault detection circuit self test passed after being re-run. Test re-runs after 15 minutes (non-EU), cable cycle, or reset button. Wall connector will not allow charging until the ground fault circuit self test passes info from manualCC_A029 Pilot level transitions to invalid voltage level Wall connector will not operate while pilot level is invalid Wall connector PCBA temperature sensor shorted, open, or too cold info from manualCC_A025 PCBA temperature sensor measured as open or short circuit Wall connector PCBA temperature reading passes rationality check info from manualCC_A015 Neutral conductor is grounded on vehicle side info from manualCC_A005 Neutral conductor conductor impedance to ground on vehicle side is less than 2 Ohms with contactors open Neutral conductor impedance to ground on vehicle is greater than 2 Ohms with contactors open Wall connector will not allow charging if there is a short between neutral and protective earth when a vehicle is connected before closing contactors Wall connector proximity line disconnected or vehicle is not providing proximity voltage info from manualCC_A019 Proximity line in charge cable has no voltage present but a vehicle is connected Proximity line in charge cable rises to a valid voltage level Wall connector will not allow charging while the proximity line is broken because it cannot determine if the cable is latched Wall connector charge handle is too hot Wall Connector handle temperature exceeds 65C Wall connector handle temperature falls below 60C Ground fault current exceeded threshold info from manualCC_A003 Ground fault current has been corrected and the test re-run. Test re-runs after 15 minutes (non-EU), cable cycle, or reset button. Wall connector will not allow charging until ground fault current path is corrected and the test re-run. info from manualCC_A018 Master and slave units in sharing network have different nameplate current ratings info from manualCC_A030 Wall connector nameplate current rating differs from other wall connector in sharing network Wall connector no longer detects units with different nameplate current rating in the sharing network and the unit is power cycled Wall connector protective earth is disconnected or grounding scheme DIP switch set incorrectly info from manualCC_A001 Wall connector AC input side ground impedance is above threshold Wall connector AC input side ground impedance has fallen below threshold for adequate time Wall connector will not allow charging until the protective earth connection is corrected Output voltage, current, and energy monitoring failure Metering hardware fails to initialize Metering hardware initializes successfully Wall Connector cannot detect welds, over-current, or meter energy. Wall Connector will not operate.

Schweregrad-Hinweise

BMS-A122 ist ein Alarm im Battery Management System-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere BMS-Codes

Alle BMS-Codes anzeigen →