CHG-F018
CHG_f018_hwLineOC
Was bedeutet CHG-F018?
Tesla Fehler-Code im Ladegerät-Modul (CHG). The charging process was interrupted by the complex programmable logic device (CPLD) due to a very sudden increase of line current above the limit threshold. The alert may be falsely set due to extreme AC line voltage disturbances from other equipment. The Gen 1 charger spec defines the alert as line peak over-current trip level shall be <= 85A with a response time < 1us. The Gen 2 charger spec defines the alert as greater than 33A (tolerance of +/- 1.7A) per phase board.
Originale Beschreibung
The charging process was interrupted by the complex programmable logic device (CPLD) due to a very sudden increase of line current above the limit threshold. The alert may be falsely set due to extreme AC line voltage disturbances from other equipment. The Gen 1 charger spec defines the alert as line peak over-current trip level shall be <= 85A with a response time < 1us. The Gen 2 charger spec defines the alert as greater than 33A (tolerance of +/- 1.7A) per phase board.
Schweregrad-Hinweise
CHG-F018 ist als Fehler (Fault) eingestuft und weist auf ein kritisches Problem im Charger-System hin. Fahren Sie nicht weiter und kontaktieren Sie sofort den Tesla-Service.