TESLA Warnung

EFUSE-W135

EFUSE_w135_condenserFanEFuseTrip

System
EFUSE
Electronic Fuse
Typ
Warnung
Kategorie
Batterie
Schweregrad
Warnung

Was bedeutet EFUSE-W135?

Tesla Warnung-Code im Elektronische Sicherung-Modul (EFUSE). This alert will trip on whenever the HVAC rail is turned off. This is expected and should be ignored, shall be fixed in future versions of firmware. This alert will raise when the condenser fan channel is faulted as seen by the E-fuse electronic control unit (ECU). This can occur if an unexpectedly high inrush current into the condenser fan or a short circuit event has occurred at the condenser fan output of the E-fuse. Another possibility is that a long current event, which exceeds the current carrying capability of the cable, has occurred. Once the E-fuse is tripped (turned off), the output will measure ~0V.

Originale Beschreibung

This alert will trip on whenever the HVAC rail is turned off. This is expected and should be ignored, shall be fixed in future versions of firmware. This alert will raise when the condenser fan channel is faulted as seen by the E-fuse electronic control unit (ECU). This can occur if an unexpectedly high inrush current into the condenser fan or a short circuit event has occurred at the condenser fan output of the E-fuse. Another possibility is that a long current event, which exceeds the current carrying capability of the cable, has occurred. Once the E-fuse is tripped (turned off), the output will measure ~0V.

Schweregrad-Hinweise

EFUSE-W135 ist eine Warnung im Electronic Fuse-System. Planen Sie zeitnah einen Servicetermin. Überwachen Sie Ihr Fahrzeug auf zusätzliche Warnungen.

Weitere EFUSE-Codes