TESLA Alarm

PCS-A075

PCS_a075_hvBusDischargeTimeout

System
PCS
Power Conversion System
Typ
Alarm
Kategorie
Batterie
Schweregrad
Alarm

Was bedeutet PCS-A075?

Tesla Alarm-Code im Leistungsumwandlungssystem-Modul (PCS). PCS DCDC timed out when attempting to discharge HV bus DCDC converter timed out when attempting to discharge HV bus Inability to perform vehicle precharge, CHAdeMO and GB DC compatibility may be impacted Input voltage measurement changed too much between switching cycles (only active in phase A) Charger AC input voltage changed too much between switching cycles Charger input line over voltage Charger AC input voltage peak level exceeds maximum input voltage peak threshold Reduced AC charge rate or inability to AC charge, possibly due to incompatible grid PCS DCDC temperature sensor is reporting irrational value DCDC converter temperature is outside expected range for more than one second DCDC converter temperature is within expected range Reduced available DCDC output power PCS DCDC HV bus voltage reading differs from HVP HV bus voltage reading by an excessive amount DCDC converter high voltage bus voltage sensor mismatches high voltage processor's sensed value on CAN for more than three seconds DCDC converter high voltage bus voltage sensor matches high voltage processor's sensed value on CAN for more than 500ms

Originale Beschreibung

PCS DCDC timed out when attempting to discharge HV bus DCDC converter timed out when attempting to discharge HV bus Inability to perform vehicle precharge, CHAdeMO and GB DC compatibility may be impacted Input voltage measurement changed too much between switching cycles (only active in phase A) Charger AC input voltage changed too much between switching cycles Charger input line over voltage Charger AC input voltage peak level exceeds maximum input voltage peak threshold Reduced AC charge rate or inability to AC charge, possibly due to incompatible grid PCS DCDC temperature sensor is reporting irrational value DCDC converter temperature is outside expected range for more than one second DCDC converter temperature is within expected range Reduced available DCDC output power PCS DCDC HV bus voltage reading differs from HVP HV bus voltage reading by an excessive amount DCDC converter high voltage bus voltage sensor mismatches high voltage processor's sensed value on CAN for more than three seconds DCDC converter high voltage bus voltage sensor matches high voltage processor's sensed value on CAN for more than 500ms

Schweregrad-Hinweise

PCS-A075 ist ein Alarm im Power Conversion System-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere PCS-Codes

Alle PCS-Codes anzeigen →