TESLA Alarm

TAS-A073

TAS_a073_underVoltage5VOnBoard

System
TAS
Thermal Architecture System
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS-A073?

Tesla Alarm-Code im Thermisches Architektursystem-Modul (TAS). On board 5V switched supply is measured to be below 4.5V. Air suspension leveling will be disabled. Systems with adaptive dampers will no longer drive current to dampers. Debug information for 10ms task errors. Set along with TaskSchedulerError. Rear left height sensor disconnected, or signal line from rear left PWM height sensor floating. Expected PWM signal received from rear left ride height sensor. Failure of a software assertion. Auto clears after 10ms of no new assertions. Reservoir air valve has reached its duty cycle (on time) limit. Reservoir air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until reservoir air valve duty cycle drops. Rear right height sensor disconnected, or signal line from rear right PWM height sensor floating. Indicates an active connection to the XCP state machine Exhaust air valve has reached its duty cycle (on time) limit. Exhaust air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until exhaust air valve duty cycle drops. Front axle has been measured to be higher than any reasonable height. Front axle has been measured to be higher than any reasonable height for an extended period. Front axle has been measured to be not be higher than any reasonable height for an extended period. Vehicle may fail to level to correct ride height. Air suspension failed to adjust to target ride height. Vehicle may not be at correct ride height. Reservoir air valve detected open circuit. Reservoir air valve commanded on but no electrical current measured. Boost air valve detected open circuit. Boost air valve commanded on but no electrical current measured. Air suspension raising will only occur via reservoir or air compressor. Static vehicle spring leak check detected a spring leak on the front right air spring. Front right air spring leak was detected with vehicle static. Sleep cycle, or successful static spring leak check. Reset can be caused by: Clock Error, Flash Error, Software Reset, Checkstop Reset, Debug Reset One or more CAN messages from CP are not being received by the ECU. One or more CAN messages from CP are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter). Successful reception of all RXd CAN messages from CP. Air suspension will assume the vehicle is not charging. Air suspension system is operating under limp home mode 30 restrictions. The ECU has detected an issue whose severity requires operating under limp home mode 30 restrictions. Air suspension leveling will be disabled, expect lowering to STANDARD via speed based restrictions on higher heights. Static vehicle spring leak check detected a spring leak on the front left air spring. Front left air spring leak was detected with vehicle static. Signal line from rear left PWM height sensor shorted to ground. Implausible condition detected on boost air valve circuit. Implausible condition detected on boost air valve circuit, possibly due to ECU hardware failure. ECU has requested suspension red warning lamp to be displayed. ECU has requested suspension red warning lamp to not be displayed. Red suspension warning lamp will be displayed.

Originale Beschreibung

On board 5V switched supply is measured to be below 4.5V. Air suspension leveling will be disabled. Systems with adaptive dampers will no longer drive current to dampers. Debug information for 10ms task errors. Set along with TaskSchedulerError. Rear left height sensor disconnected, or signal line from rear left PWM height sensor floating. Expected PWM signal received from rear left ride height sensor. Failure of a software assertion. Auto clears after 10ms of no new assertions. Reservoir air valve has reached its duty cycle (on time) limit. Reservoir air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until reservoir air valve duty cycle drops. Rear right height sensor disconnected, or signal line from rear right PWM height sensor floating. Indicates an active connection to the XCP state machine Exhaust air valve has reached its duty cycle (on time) limit. Exhaust air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until exhaust air valve duty cycle drops. Front axle has been measured to be higher than any reasonable height. Front axle has been measured to be higher than any reasonable height for an extended period. Front axle has been measured to be not be higher than any reasonable height for an extended period. Vehicle may fail to level to correct ride height. Air suspension failed to adjust to target ride height. Vehicle may not be at correct ride height. Reservoir air valve detected open circuit. Reservoir air valve commanded on but no electrical current measured. Boost air valve detected open circuit. Boost air valve commanded on but no electrical current measured. Air suspension raising will only occur via reservoir or air compressor. Static vehicle spring leak check detected a spring leak on the front right air spring. Front right air spring leak was detected with vehicle static. Sleep cycle, or successful static spring leak check. Reset can be caused by: Clock Error, Flash Error, Software Reset, Checkstop Reset, Debug Reset One or more CAN messages from CP are not being received by the ECU. One or more CAN messages from CP are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter). Successful reception of all RXd CAN messages from CP. Air suspension will assume the vehicle is not charging. Air suspension system is operating under limp home mode 30 restrictions. The ECU has detected an issue whose severity requires operating under limp home mode 30 restrictions. Air suspension leveling will be disabled, expect lowering to STANDARD via speed based restrictions on higher heights. Static vehicle spring leak check detected a spring leak on the front left air spring. Front left air spring leak was detected with vehicle static. Signal line from rear left PWM height sensor shorted to ground. Implausible condition detected on boost air valve circuit. Implausible condition detected on boost air valve circuit, possibly due to ECU hardware failure. ECU has requested suspension red warning lamp to be displayed. ECU has requested suspension red warning lamp to not be displayed. Red suspension warning lamp will be displayed.

Schweregrad-Hinweise

TAS-A073 ist ein Alarm im Thermal Architecture System-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS-Codes

TAS_a001 TAS_a002 Sudden power loss.... TAS_a003 TAS_a012 TAS_a015 Bootup without indication.... TAS_a021 TAS_a022 TAS_a025
Alle TAS-Codes anzeigen →