TESLA Alarm

TAS2-A032

TAS2_a032_PWMerrorRL

System
TAS2
Thermal Architecture System v2
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS2-A032?

Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a032_PWMerrorRL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

Originale Beschreibung

The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a032_PWMerrorRL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

Schweregrad-Hinweise

TAS2-A032 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS2-Codes