THC-W0148
THC_w0148_refrigerantLow
Was bedeutet THC-W0148?
Tesla Warnung-Code im THC-Modul (THC). The THC_w0148_refrigerantLow? warning was first released in FW 2017.24+ The THC_w0148_refrigerantLow alert shall be set if the following conditions are met for 60 seconds: THC is initialized The ambient temperature sensor is not faultedThe ambient temperature > 0 deg C Refrigerant discharge temp > 0 deg CThere are no refrigerant discharge temperature alerts (THC_a0137_rfrgDisTemp or THC_a0138_rfrgDisTempRange) There are no refrigerant suction temperature alerts (THC_a0142_rfrgSuctPress) or THC_a0145_rfrgSuctPressRange) The refrigerant discharge pressure < 0.25 bar The THC_w0148_refrigerantLow alert shall be cleared if the following conditions are met for 30 seconds: THC is initialized The ambient temperature sensor is not faulted The ambient temperature > 0 deg C Refrigerant discharge temp > 0 deg C There are no refrigerant discharge temperature alerts (THC_a0137_rfrgDisTemp or THC_a0138_rfrgDisTempRange) There are no refrigerant suction temperature alerts (THC_a0142_rfrgSuctPress) or THC_a0145_rfrgSuctPressRange) The refrigerant discharge pressure > 1.5 bar? Note: This warning will be customer facing in 2017.50.
Originale Beschreibung
The THC_w0148_refrigerantLow? warning was first released in FW 2017.24+ The THC_w0148_refrigerantLow alert shall be set if the following conditions are met for 60 seconds: THC is initialized The ambient temperature sensor is not faultedThe ambient temperature > 0 deg C Refrigerant discharge temp > 0 deg CThere are no refrigerant discharge temperature alerts (THC_a0137_rfrgDisTemp or THC_a0138_rfrgDisTempRange) There are no refrigerant suction temperature alerts (THC_a0142_rfrgSuctPress) or THC_a0145_rfrgSuctPressRange) The refrigerant discharge pressure < 0.25 bar The THC_w0148_refrigerantLow alert shall be cleared if the following conditions are met for 30 seconds: THC is initialized The ambient temperature sensor is not faulted The ambient temperature > 0 deg C Refrigerant discharge temp > 0 deg C There are no refrigerant discharge temperature alerts (THC_a0137_rfrgDisTemp or THC_a0138_rfrgDisTempRange) There are no refrigerant suction temperature alerts (THC_a0142_rfrgSuctPress) or THC_a0145_rfrgSuctPressRange) The refrigerant discharge pressure > 1.5 bar? Note: This warning will be customer facing in 2017.50.
Schweregrad-Hinweise
THC-W0148 ist eine Warnung im THC-System. Planen Sie zeitnah einen Servicetermin. Überwachen Sie Ihr Fahrzeug auf zusätzliche Warnungen.