Hyundai IONIQ 6
The Hyundai IONIQ 6 is an electric streamliner sedan on the E-GMP platform with 800V architecture and up to 361 miles of range.
2023–present · Sedan · US, EU, Global
Fault Code List
Showing 43 fault codes
P1A6F Critical Airbag Deployment Signal Circuit High
P1A71 Critical Airbag Deployment Signal Circuit Low
P1A77 Caution Check Generator Belt
P1A86 Warning Inappropriate and Low SOC (State of Charge)
P1A88 Warning DC/DC Converter Cooling System Fault
P1A89 Warning DC/DC Converter Current Sensor Fault
P1AA6 Warning High Voltage Battery Management System Malfunction
P1AA7 Warning High Voltage Battery Cell Voltage Deviation (BMS Malfunction)
P1AAC Warning High Voltage Battery Cell Overcharge
P1AAD Warning High Voltage Battery Cell Over-Discharge
P1AAE Critical High Voltage Battery Isolation Fault
P1AAF Warning High Voltage Battery Ground Fault
P1AB0 Warning High Voltage Battery Pack Connection Fault
P1AD3 Warning High Voltage Battery Abnormal Performance (Charging Inhibited)
P1B03 Warning Auxiliary Battery Temperature Sensor Circuit Malfunction
P1B1D Warning OPI (On-board Power Isolator) Fault
P1B25 Warning High Voltage Battery Path Fault
P1B62 Warning High Voltage Battery Current Sensor Circuit Malfunction
P1B67 Warning High Voltage Battery Current Sensor Fault
P1B70 Critical High Voltage Battery Voltage Too Low
P1B71 Critical High Voltage Battery Voltage Too High
P1B74 Warning High Voltage Battery Voltage Sensor Circuit Malfunction
P1B75 Warning High Voltage Battery Current Value Error
P1B76 Warning High Voltage Battery Relay Fault
P1B77 Warning High Voltage Battery Precharging Fault
P1B7700 Warning High Voltage Battery ICCU (Integrated Charging Control Unit) Fault
P1B78 Warning High Voltage Battery Temperature Sensor Level 1 Fault
P1B79 Warning High Voltage Battery Temperature Sensor Level 2 Fault
P1B84 Warning High Voltage Battery Cell Voltage Deviation Too High
P1B95 Warning High Voltage Battery Pack Deterioration
P1B96 Warning High Voltage Battery Voltage Sensor Fault
P1B97 Warning High Voltage Battery Temperature Sensor Fault
P1BA0 Warning High Voltage Battery and MCU Cooling Fan Relay Fault
P1BA1 Warning High Voltage Battery Cooling Fan Fault
P1C28 Warning OPI (On-board Power Isolator) Current High
P1C2B Warning OPI Hall Sensor Error
P1C64 Caution Drive Motor Phase A Cable Circuit Open
P1C6A Caution Generator Phase Cable Circuit Open
P1C76 Warning Generator Position Sensor Not Learned
U1004 Caution SCP (J1850) Invalid or Missing Data for EEC Programming
U1005 Caution SCP (J1850) Invalid or Missing Data for EEC Programming
U1006 Caution SCP (J1850) Invalid or Missing Data for Primary Id
U1116 Caution SCP (J1850) Invalid or Missing Data for Electrical Energy Management