DI_w166
DI_w166_hvilOutOfBounds
What does DI_w166 mean?
Tesla warning code in the Drive Inverter (DI) module. The drive inverter (DI) has detected that the high voltage interlock loop (HVIL) voltage is outside of the specified range. This alert only applies to small drive units. This alert is set if HVIL voltage is +/-0.3 volts or +/- 1.5ma the nominal value. This alert can be falsely triggered when the DI is outputting higher torque. This alert alone is not enough to identify an HVIL issue.
Original Description
The drive inverter (DI) has detected that the high voltage interlock loop (HVIL) voltage is outside of the specified range. This alert only applies to small drive units. This alert is set if HVIL voltage is +/-0.3 volts or +/- 1.5ma the nominal value. This alert can be falsely triggered when the DI is outputting higher torque. This alert alone is not enough to identify an HVIL issue.
Severity Notes
DI_w166 is a Warning in the Drive Inverter system. Schedule service soon. Monitor your vehicle for additional warnings.
Other DI Codes