TESLA Warning

DI-W166

DI_w166_hvilOutOfBounds

System
DI
Drive Inverter
Type
Warning
Category
Motor
Severity
Warning

What does DI-W166 mean?

Tesla warning code in the Drive Inverter (DI) module. The drive inverter (DI) has detected that the high voltage interlock loop (HVIL) voltage is outside of the specified range. This alert only applies to small drive units. This alert is set if HVIL voltage is +/-0.3 volts or +/- 1.5ma the nominal value. This alert can be falsely triggered when the DI is outputting higher torque. This alert alone is not enough to identify an HVIL issue.

Original Description

The drive inverter (DI) has detected that the high voltage interlock loop (HVIL) voltage is outside of the specified range. This alert only applies to small drive units. This alert is set if HVIL voltage is +/-0.3 volts or +/- 1.5ma the nominal value. This alert can be falsely triggered when the DI is outputting higher torque. This alert alone is not enough to identify an HVIL issue.

Severity Notes

DI-W166 is a Warning in the Drive Inverter system. Schedule service soon. Monitor your vehicle for additional warnings.

Other DI Codes

DI_a001 DI_a002 Park button pressed during stalk request Rising edge of stal... DI_a010 DI_a012 DI_a013 DI_a015 DI_a016 DI_a017
View all DI codes →