TESLA Alert

TAS-A076

TAS_a076_overVoltage5VOffBoard

System
TAS
Thermal Architecture System
Type
Alert
Category
HVAC
Severity
Alert

What does TAS-A076 mean?

Tesla alert code in the Thermal Architecture System (TAS) module. Off board 5V switched supply is measured to be over 5.5V. Front left air valve detected open circuit. Front left air valve commanded on but no electrical current measured. An issue is indicated from the NVRAM Manager. Record not found, CRC mismatch, Version mismatch, Version upgrade. Ride height calibration, target suspension level, crash status, or learned VIN may be lost. Pressure sensor signal voltage too low; likely disconnected. Pressure sensor signal received is too low. Pressure sensor signal received is in range. One or more CAN messages from DI are not being received by the ECU. One or more CAN messages from DI are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter). Successful reception of all RXd CAN messages from DI. Air suspension functionality may be reduced. Excessive leveling corrections may occur and system may not lower suspension at higher speeds. No valid ride height sensor calibrations have been saved to the ECU. Received ride height sensor calibration values are inside of allowable range. Air suspension will only level upon manual requests. Auto leveling of suspension is disabled.

Original Description

Off board 5V switched supply is measured to be over 5.5V. Front left air valve detected open circuit. Front left air valve commanded on but no electrical current measured. An issue is indicated from the NVRAM Manager. Record not found, CRC mismatch, Version mismatch, Version upgrade. Ride height calibration, target suspension level, crash status, or learned VIN may be lost. Pressure sensor signal voltage too low; likely disconnected. Pressure sensor signal received is too low. Pressure sensor signal received is in range. One or more CAN messages from DI are not being received by the ECU. One or more CAN messages from DI are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter). Successful reception of all RXd CAN messages from DI. Air suspension functionality may be reduced. Excessive leveling corrections may occur and system may not lower suspension at higher speeds. No valid ride height sensor calibrations have been saved to the ECU. Received ride height sensor calibration values are inside of allowable range. Air suspension will only level upon manual requests. Auto leveling of suspension is disabled.

Severity Notes

TAS-A076 is an Alert in the Thermal Architecture System system. It is generally safe to continue driving, but have it checked at your next scheduled service.

Other TAS Codes

TAS_a001 TAS_a002 Sudden power loss.... TAS_a003 TAS_a012 TAS_a015 Bootup without indication.... TAS_a021 TAS_a022 TAS_a025
View all TAS codes →