TAS-A210
TAS_a210_outOfRangeCalibration
What does TAS-A210 mean?
Tesla alert code in the Thermal Architecture System (TAS) module. Received ride height sensor calibration values are outside of allowable range. Air suspension will level to incorrect ride height. Rear left air valve has reached its duty cycle (on time) limit. Rear left air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until rear left air valve duty cycle drops. Air suspension system is operating under limp home mode 10 restrictions. The ECU has detected an issue whose severity requires operating under limp home mode 10 restrictions. Boost air valve has reached its duty cycle (on time) limit. Boost air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling via the compressor boost valve will be temporarily disabled until boost air valve duty cycle drops. A task init function returns with an error. If an init routine fails, software may not opperate correctly. Front right air valve has reached its duty cycle (on time) limit. Front right air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until front right air valve duty cycle drops.
Original Description
Received ride height sensor calibration values are outside of allowable range. Air suspension will level to incorrect ride height. Rear left air valve has reached its duty cycle (on time) limit. Rear left air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until rear left air valve duty cycle drops. Air suspension system is operating under limp home mode 10 restrictions. The ECU has detected an issue whose severity requires operating under limp home mode 10 restrictions. Boost air valve has reached its duty cycle (on time) limit. Boost air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling via the compressor boost valve will be temporarily disabled until boost air valve duty cycle drops. A task init function returns with an error. If an init routine fails, software may not opperate correctly. Front right air valve has reached its duty cycle (on time) limit. Front right air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until front right air valve duty cycle drops.
Severity Notes
TAS-A210 is an Alert in the Thermal Architecture System system. It is generally safe to continue driving, but have it checked at your next scheduled service.