TESLA Alert

VCFRONT-A247

VCFRONT_a247_evapSolenoidFault

System
VCFRONT
Vehicle Controller Front
Type
Alert
Category
Network
Severity
Alert

What does VCFRONT-A247 mean?

Tesla alert code in the Vehicle Controller Front (VCFRONT) module. The refrigerant evaporator solenoid has encountered an electrical fault (short, disconnect or internal). HVAC cabin cooling (air conditioning) and powertrain performance may be limited. The refrigerant evaporator solenoid is consuming less than 0.2 Amps, or greater than 2.0 Amps, when active The refrigerant evaporator solenoid is consuming between 0.2 Amps and 2.0 Amps when active HVAC cabin cooling (air conditioning) and powertrain cooling may be limited

Original Description

The refrigerant evaporator solenoid has encountered an electrical fault (short, disconnect or internal). HVAC cabin cooling (air conditioning) and powertrain performance may be limited. The refrigerant evaporator solenoid is consuming less than 0.2 Amps, or greater than 2.0 Amps, when active The refrigerant evaporator solenoid is consuming between 0.2 Amps and 2.0 Amps when active HVAC cabin cooling (air conditioning) and powertrain cooling may be limited

Severity Notes

VCFRONT-A247 is an Alert in the Vehicle Controller Front system. It is generally safe to continue driving, but have it checked at your next scheduled service.