TESLA Alarm

PCS-A106

PCS_a106_clockSourceNotFromExternalCrystal

System
PCS
Power Conversion System
Typ
Alarm
Kategorie
Batterie
Schweregrad
Alarm

Was bedeutet PCS-A106?

Tesla Alarm-Code im Leistungsumwandlungssystem-Modul (PCS). PCS bootloader configured the clock source to use the internal clock (INTOSC2), because the DSP has reported a missing clock from the external crystal oscillator On boot, PCS is not using the external crystal oscillator (XTALOSC) No clear condition during operation. The set condition is evaluated on boot, and will remain set until power cycled or reset. Internal oscillator is less precise, potentially has system behavior impact Charger detects unknown grid configuration Charger state machine clears faults Inability to AC charge, possibly due to incompatible grid

Originale Beschreibung

PCS bootloader configured the clock source to use the internal clock (INTOSC2), because the DSP has reported a missing clock from the external crystal oscillator On boot, PCS is not using the external crystal oscillator (XTALOSC) No clear condition during operation. The set condition is evaluated on boot, and will remain set until power cycled or reset. Internal oscillator is less precise, potentially has system behavior impact Charger detects unknown grid configuration Charger state machine clears faults Inability to AC charge, possibly due to incompatible grid

Schweregrad-Hinweise

PCS-A106 ist ein Alarm im Power Conversion System-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.