TESLA Alarm

TAS-A225

TAS_a225_galleryPressureTooHigh

System
TAS
Thermal Architecture System
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS-A225?

Tesla Alarm-Code im Thermisches Architektursystem-Modul (TAS). Gallery pressure was measured to be higher than expected under any operating condition. Front axle has been measured to be lower than any reasonable height. Front axle has been measured to be lower than any reasonable height for an extended period. Front axle has been measured to be not be lower than any reasonable height for an extended period. Debug information for 100ms task errors. Set along with TaskSchedulerError. Front right air valve detected short circuit. Front right air valve output shorted to ground or battery voltage. One or more CAN messages from GTW are not being received by the ECU. One or more CAN messages from GTW are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter). Successful reception of all RXd CAN messages from GTW. Air suspension functionality may be reduced. Air suspension may not be able to recover from corrected faults. Debug information for 1000ms task errors. Set along with TaskSchedulerError. Rear right air valve detected open circuit. Rear right air valve commanded on but no electrical current measured. Front left air valve has reached its duty cycle (on time) limit. Front left air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until front left air valve duty cycle drops.

Originale Beschreibung

Gallery pressure was measured to be higher than expected under any operating condition. Front axle has been measured to be lower than any reasonable height. Front axle has been measured to be lower than any reasonable height for an extended period. Front axle has been measured to be not be lower than any reasonable height for an extended period. Debug information for 100ms task errors. Set along with TaskSchedulerError. Front right air valve detected short circuit. Front right air valve output shorted to ground or battery voltage. One or more CAN messages from GTW are not being received by the ECU. One or more CAN messages from GTW are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter). Successful reception of all RXd CAN messages from GTW. Air suspension functionality may be reduced. Air suspension may not be able to recover from corrected faults. Debug information for 1000ms task errors. Set along with TaskSchedulerError. Rear right air valve detected open circuit. Rear right air valve commanded on but no electrical current measured. Front left air valve has reached its duty cycle (on time) limit. Front left air valve has dropped below its duty cycle (on time) limit, plus some hysteresis. Air suspension leveling will be temporarily disabled until front left air valve duty cycle drops.

Schweregrad-Hinweise

TAS-A225 ist ein Alarm im Thermal Architecture System-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS-Codes

TAS_a001 TAS_a002 Sudden power loss.... TAS_a003 TAS_a012 TAS_a015 Bootup without indication.... TAS_a021 TAS_a022 TAS_a025
Alle TAS-Codes anzeigen →