TESLA Alarm

TAS2-A039

TAS2_a039_PWMopenFR

System
TAS2
Thermal Architecture System v2
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS2-A039?

Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front right (FR) height sensor PWM signal has had a duty cycle equal to 100% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_OPEN_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front right (FR) height sensor PWM signal has had a duty cycle less than 100% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

Originale Beschreibung

The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front right (FR) height sensor PWM signal has had a duty cycle equal to 100% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_OPEN_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front right (FR) height sensor PWM signal has had a duty cycle less than 100% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

Schweregrad-Hinweise

TAS2-A039 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS2-Codes

Alle TAS2-Codes anzeigen →