TESLA Alarm

TAS2-A077

TAS2_a077_pressureSigVTooLow

System
TAS2
Thermal Architecture System v2
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS2-A077?

Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). The Tesla Air Suspension Controller (TAS) supplies the system pressure sensor (located in the valve block) with 5V, and observes the analog pressure signal voltage to evaluate the pressure. In normal operation of the pressure sensor, the signal should range from approximately 10-90% of the supply voltage. Set: The gallery pressure sensor signal is below 4% the supply voltage (nominally 5V). voltage < 0.2 V Clear: The gallery pressure sensor signal is above 4% the supply voltage (nominally 5V). voltage > 0.2 V To convert from percent to bar: p(bar) = 23.7248 * p(percent) - 1.375

Originale Beschreibung

The Tesla Air Suspension Controller (TAS) supplies the system pressure sensor (located in the valve block) with 5V, and observes the analog pressure signal voltage to evaluate the pressure. In normal operation of the pressure sensor, the signal should range from approximately 10-90% of the supply voltage. Set: The gallery pressure sensor signal is below 4% the supply voltage (nominally 5V). voltage < 0.2 V Clear: The gallery pressure sensor signal is above 4% the supply voltage (nominally 5V). voltage > 0.2 V To convert from percent to bar: p(bar) = 23.7248 * p(percent) - 1.375

Schweregrad-Hinweise

TAS2-A077 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS2-Codes

Alle TAS2-Codes anzeigen →