TAS2-A129
TAS2_a129_openCircuitFL
Was bedeutet TAS2-A129?
Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). This alert checks for open circuit faults every 10ms. Voltage and current are measured by Tesla Air Suspension Controller (TASC) when the front left (FL) valve is commanded with 12V. Set: The FL valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6V current is sensed below 0.02A Clear: Single drive-rail cycle
Originale Beschreibung
This alert checks for open circuit faults every 10ms. Voltage and current are measured by Tesla Air Suspension Controller (TASC) when the front left (FL) valve is commanded with 12V. Set: The FL valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6V current is sensed below 0.02A Clear: Single drive-rail cycle
Schweregrad-Hinweise
TAS2-A129 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.