Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the boost valve is commanded with 12V. Set:The boost valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6V current is sensed below 0.02AClear: Single drive-rail cycle

Originale Beschreibung

This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the boost valve is commanded with 12V. Set:The boost valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6V current is sensed below 0.02AClear: Single drive-rail cycle

Schweregrad-Hinweise

TAS2-A135 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.