TESLA Alarm

TAS2-A222

TAS2_a222_compressorPrefillFault

System
TAS2
Thermal Architecture System v2
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS2-A222?

Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). The alert checks for compressor prefill faults every 100ms. Set: Compressor prefill will timeout during a prefill operation if the pressure derivative remains under 1 bar/second for 10 seconds. Clear: Single drive-rail cycle Note: A prefill operation is performed before opening the valves to an air spring or the reservoir. Prefill works by activating the compressor with the spring and reservoir valves closed, so that the gallery pressure increases. This reduces the change in pressure upon opening of the valves, similar to the precharge sequence for the high-voltage battery or on-board chargers. Prefill will fail if: a valve is open or leaking (pressure escapes from the gallery) the compressor does not run compressed air escapes before the valve block

Originale Beschreibung

The alert checks for compressor prefill faults every 100ms. Set: Compressor prefill will timeout during a prefill operation if the pressure derivative remains under 1 bar/second for 10 seconds. Clear: Single drive-rail cycle Note: A prefill operation is performed before opening the valves to an air spring or the reservoir. Prefill works by activating the compressor with the spring and reservoir valves closed, so that the gallery pressure increases. This reduces the change in pressure upon opening of the valves, similar to the precharge sequence for the high-voltage battery or on-board chargers. Prefill will fail if: a valve is open or leaking (pressure escapes from the gallery) the compressor does not run compressed air escapes before the valve block

Schweregrad-Hinweise

TAS2-A222 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS2-Codes

Alle TAS2-Codes anzeigen →