TESLA Alarm

TAS2-A225

TAS2_a225_galleryPressureTooHigh

System
TAS2
Thermal Architecture System v2
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS2-A225?

Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). The alert checks for high gallery pressure faults every 100ms. Set: Gallery pressure is greater than 19 bar for 1 second and Tesla Air Suspension (TAS) is in one of the following states: TAS_state = Fill_reservoir_from_CompressorTAS_state = Fill_spring_reservoir_from_CompressorTAS_state = Fill_spring_from_CompressorTAS_state = Fill_spring_from_Boost Clear: Single drive-rail cycle This indicates that the gallery pressure (where the pressure sensor is located) is over 19 bar, and has stayed at over 19 bar for one second. The system pressure for TAS is 18 bar, so while the system is functioning normally, pressure should never be over 19 bar, especially for over one second.

Originale Beschreibung

The alert checks for high gallery pressure faults every 100ms. Set: Gallery pressure is greater than 19 bar for 1 second and Tesla Air Suspension (TAS) is in one of the following states: TAS_state = Fill_reservoir_from_CompressorTAS_state = Fill_spring_reservoir_from_CompressorTAS_state = Fill_spring_from_CompressorTAS_state = Fill_spring_from_Boost Clear: Single drive-rail cycle This indicates that the gallery pressure (where the pressure sensor is located) is over 19 bar, and has stayed at over 19 bar for one second. The system pressure for TAS is 18 bar, so while the system is functioning normally, pressure should never be over 19 bar, especially for over one second.

Schweregrad-Hinweise

TAS2-A225 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere TAS2-Codes

Alle TAS2-Codes anzeigen →