TESLA Alarm

VCFRONT-A373

VCFRONT_a373_chillerControlFlooding

System
VCFRONT
Vehicle Controller Front
Typ
Alarm
Kategorie
Netzwerk
Schweregrad
Alarm

Was bedeutet VCFRONT-A373?

Tesla Alarm-Code im Fahrzeugsteuerung vorne-Modul (VCFRONT). The chiller control is in a state where the compressor could be flooding. HVAC cabin cooling (air conditioning) and powertrain performance may be limited. The chiller's superheat is less than 1 deg C for more than 3 seconds while there is chiller demand The chiller control has restarted or the superheat temperature is above the minimum threshold of 1 deg C

Originale Beschreibung

The chiller control is in a state where the compressor could be flooding. HVAC cabin cooling (air conditioning) and powertrain performance may be limited. The chiller's superheat is less than 1 deg C for more than 3 seconds while there is chiller demand The chiller control has restarted or the superheat temperature is above the minimum threshold of 1 deg C

Schweregrad-Hinweise

VCFRONT-A373 ist ein Alarm im Vehicle Controller Front-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.

Weitere VCFRONT-Codes

Alle VCFRONT-Codes anzeigen →