TESLA Alert

TAS2-A033

TAS2_a033_PWMerrorRR

System
TAS2
Thermal Architecture System v2
Type
Alert
Category
HVAC
Severity
Alert

What does TAS2-A033 mean?

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a033_PWMerrorFL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

Original Description

The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every repeated fault and triggers the fault at a threshold of 50. The weighted counter decrements by 1 for every valid reading and clears the fault when it reaches 0. TAS2_a033_PWMerrorFL will trigger if any of the following faults are set: PWM_OVER_MAX_DUTY -Set:The height sensor PWM signal has had a duty cycle greater than 87.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle less than 87.5% for 500ms. PWM_UNDER_MIN_DUTY -Set: The height sensor PWM signal has had a duty cycle less than 12.5% for 50ms. -Clear:The height sensor PWM signal has had a duty cycle greater than 12.5% for 500ms. PWM_OVER_MAX_PERIOD -Set: The height sensor PWM signal has had a period greater than 0.00131579 seconds for 50ms. -Clear:The height sensor PWM signal has had a period less than 0.00131579 seconds for 500ms. PWM_UNDER_MIN_PERIOD -Set: The height sensor PWM signal has had a period less than 0.00119048 seconds for 50ms. -Clear:The height sensor PWM signal has had a period greater than 0.00119048 seconds for 500ms. PWM_OVER_MAX_DELTA_DUTY (cannot be set if transitioning to/from 0 or 100% duty cycle) -Set: The height sensor PWM duty cycle has changed by more than 33% (3.3 * 10ms alert period) since its previous cycle for 50ms. -Clear: The height sensor PWM duty cycle has changed by less than 33% (3.3 * 10ms alert period) since its previous cycle for 500ms.

Severity Notes

TAS2-A033 is an Alert in the Thermal Architecture System v2 system. It is generally safe to continue driving, but have it checked at your next scheduled service.

Other TAS2 Codes

View all TAS2 codes →