TESLA Alert

TAS2-A035

TAS2_a035_PWMshortFR

System
TAS2
Thermal Architecture System v2
Type
Alert
Category
HVAC
Severity
Alert

What does TAS2-A035 mean?

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front right (FR) height sensor PWM signal has had a duty cycle equal to 0% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_SHORT_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front right (FR) height sensor PWM signal has had a duty cycle greater than 0% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

Original Description

The alert checks for height sensor PWM faults every 10ms. A weighted counter increments by 10 for every faulted reading and triggers the fault at a threshold of 50. Set: The front right (FR) height sensor PWM signal has had a duty cycle equal to 0% for 50ms. A weighted counter increments by 10 for every FAULT_TYPE_PWM_SHORT_CIRCUIT and triggers the fault at a threshold of 50. Clear: The front right (FR) height sensor PWM signal has had a duty cycle greater than 0% for 500ms. A weighted counter decrements (from threshold of 50) by 1 for every valid reading and clears the fault when it reaches 0.

Severity Notes

TAS2-A035 is an Alert in the Thermal Architecture System v2 system. It is generally safe to continue driving, but have it checked at your next scheduled service.

Other TAS2 Codes

View all TAS2 codes →