TAS2-A133
TAS2_a133_openCircuitReservoir
What does TAS2-A133 mean?
Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the reservoir valve is commanded with 12V. Set: The reservoir valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02AClear: Single drive-rail cycle
Original Description
This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the reservoir valve is commanded with 12V. Set: The reservoir valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02AClear: Single drive-rail cycle
Severity Notes
TAS2-A133 is an Alert in the Thermal Architecture System v2 system. It is generally safe to continue driving, but have it checked at your next scheduled service.