TESLA Alert

TAS2-A162

TAS2_a162_compressorValveOpenGND

System
TAS2
Thermal Architecture System v2
Type
Alert
Category
HVAC
Severity
Alert

What does TAS2-A162 mean?

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for disconnected ground to the exhaust/boost valves every 10ms. Set: If both of the following are true: Open circuit fault is true when a valve is commanded open.Short circuit fault is true when a valve is commanded close.Clear: Single drive-rail cycle

Original Description

This alert checks for disconnected ground to the exhaust/boost valves every 10ms. Set: If both of the following are true: Open circuit fault is true when a valve is commanded open.Short circuit fault is true when a valve is commanded close.Clear: Single drive-rail cycle

Severity Notes

TAS2-A162 is an Alert in the Thermal Architecture System v2 system. It is generally safe to continue driving, but have it checked at your next scheduled service.

Other TAS2 Codes

View all TAS2 codes →