TESLA Alert

TAS2-A227

TAS2_a227_PWMfastDetectFR

System
TAS2
Thermal Architecture System v2
Type
Alert
Category
HVAC
Severity
Alert

What does TAS2-A227 mean?

Tesla alert code in the Thermal Architecture System v2 (TAS2) module. Alert is set to indicate that the front right (FR) height sensor temporarily faulted when 100%, 0%, or a large delta in the duty cycle was read from the front left (FL) pulse width modulation (PWM) height-sensor. Duty cycle of 100% indicates an open circuit. Duty cycle of 0% indicates a short to ground. The alert will clear when one second of expected values is received from the FL height-sensor.

Original Description

Alert is set to indicate that the front right (FR) height sensor temporarily faulted when 100%, 0%, or a large delta in the duty cycle was read from the front left (FL) pulse width modulation (PWM) height-sensor. Duty cycle of 100% indicates an open circuit. Duty cycle of 0% indicates a short to ground. The alert will clear when one second of expected values is received from the FL height-sensor.

Severity Notes

TAS2-A227 is an Alert in the Thermal Architecture System v2 system. It is generally safe to continue driving, but have it checked at your next scheduled service.

Other TAS2 Codes