TESLA Alarm

TAS2-A130

TAS2_a130_openCircuitFR

System
TAS2
Thermal Architecture System v2
Typ
Alarm
Kategorie
Klimaanlage
Schweregrad
Alarm

Was bedeutet TAS2-A130?

Tesla Alarm-Code im Thermisches Architektursystem v2-Modul (TAS2). This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front right (FR) valve is commanded with 12V. Set: The FR valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02A Clear: Single drive-rail cycle

Originale Beschreibung

This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front right (FR) valve is commanded with 12V. Set: The FR valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02A Clear: Single drive-rail cycle

Schweregrad-Hinweise

TAS2-A130 ist ein Alarm im Thermal Architecture System v2-System. Es ist im Allgemeinen sicher, weiterzufahren, aber lassen Sie es beim nächsten geplanten Service überprüfen.