TAS2-A130
TAS2_a130_openCircuitFR
What does TAS2-A130 mean?
Tesla alert code in the Thermal Architecture System v2 (TAS2) module. This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front right (FR) valve is commanded with 12V. Set: The FR valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02A Clear: Single drive-rail cycle
Original Description
This alert checks for open circuit faults every 10ms. Voltage and current are measured by the Tesla Air Suspension Controller (TASC) when the front right (FR) valve is commanded with 12V. Set: The FR valve is commanded and both of the following are true: voltage is sensed between 11.4 - 12.6Vcurrent is sensed below 0.02A Clear: Single drive-rail cycle
Severity Notes
TAS2-A130 is an Alert in the Thermal Architecture System v2 system. It is generally safe to continue driving, but have it checked at your next scheduled service.